WeChat service QR code


Direct Reading Spectrometer

Your current page: Home > Products > Direct Reading Spectrometer

201902121134300602 (2).jpg

Instrument introduction:

INNOVATE CCD OIL5000 uses rotating disk electrode atomic emission spectroscopy technology to detect metal abrasive particles and pollutants in lubricating oil or hydraulic oil, which is consistent with the requirements of ASTM D6595 standard. It also complies with ASTM D6728 (Determination Standard for Alkali Pollutants in Fuel). Oil element spectrum analyzer, no need to dilute oil, no auxiliary solvent or gas. Simultaneous analysis of multiple abrasive elements within 30 seconds, allowing users to quickly detect the oil status of the equipment. The oil spectrum analysis software comes with intuitive and easy operation, which can analyze multiple elements at the same time. Application fields: military, aviation, railway, ocean fleet, mines, refineries, power plants, oil plants, oil recovery, manufacturing plants, commercial laboratories, racing teams and any other industries that use lubricants.

Technical Parameters

Optical system:

1. Multi-block high-performance CCD detector system;

2. 3,648 pixels per CCD;

3. A maximum resolution of 58,368 pixels (14 x 3,648 pixels);

4. High-performance holographic diffraction grating with 2700 grating lines / mm;

5. Temperature stabilization system;

6, using special materials to deal with drift;

7. Focal length: 500 mm;

8. Spectral line wavelength: 130-800 nm is determined by the choice of diffraction grating;

9. The choice of grating is determined according to the analysis elements and analysis procedures;

10. Automatic tracing of all optical system;

11. The sealed vacuum optical room can avoid the interference of dust and light;

Spark Power:

1. Oscillating arc discharge control, electronic acquisition and data readout system;

2. The electronic system has microprocessor-controlled multi-channel integration and data system acquisition functions;

3. High-speed 16-bit analog-to-digital converter;

4, ISP mixed signal Flash microcontroller 100MHz;

5. Multiple connection sources;

6. High-speed readout and high-speed USB interface support fast data control and processing system;

7. A maximum of 16 CCD modules can be selected by the manufacturer according to the application;

Analyzing Software:

1. User-friendly graphical interface;

2. Create or modify analysis programs;

3. Common operation function keys;

4. Selectable output methods (intensity, intensity ratio, uncorrected concentration, corrected concentration, etc.);

5. Automatic standardization;

6. Standard deviation and relative standard deviation functions;

7. Reference material library;

8. It can mark the element analysis results beyond the working curve range;

9. Statistical function software;

10. Statistical calculations;

11. It can print all the excitation results or the average results of up to 100 excitations, and their standard deviation and relative standard deviation;

power supply:

1, 220V +/- 10%, single phase, 50/60 Hz, 10 A, 1.5 KVA;

specification:

1. Size: L110 x D48 x H68 cm;

2. Weight: about 150 Kg;

Performance characteristics:

1. The testing method and accuracy meet ASTM D6595 testing standards;

2. Full spectrum analysis technology of CCD detector, it is convenient to configure more substrates and elements, and it is convenient to add configuration at the user site;

3. Ultra-long focal length design guarantees good resolution of the instrument;

4. The spectral line processing algorithm can perform functions such as calibration, background subtraction, and interference correction;

5, high detection accuracy, detection limit is less than 1ppm;

6, the sample test speed is fast, the single test process is less than 30 seconds;

7. The instrument is simple and convenient to use and maintain, with low professional requirements for personnel;

8. The sample does not need to be pretreated, and no additional chemical reagents are used. The testing process is safe and environmentally friendly;

9. Work around the clock, with excellent stability and reliability;

 

 